Product Overview
Product Details:
Display Mode | 1.8'' TFT colour screen,LED blacklight |
Display resolution: | 160 x 128 pixels |
Volume range | 0~10L |
Working current | 60 mA |
Power Supply | DC3.7V rechargeable lithium battery |
Bluetooth | Yes |
Brand | Contec |
Dimensions | 97mmx 89mmx 36mm |
Flow Accuracy | +-10% or +-0.3L/s |
Flow Range | 1 L/S ~16L/S |
Mode | Automatic |
Model Name/No. | SP10 |
Printer | No |
Real Time Testing | Yes |
Software Support | Yes |
Synonyms | Diagnostic Spirometer,Spirometry Machine |
Tests Performed | FVC,FEV1,FEV1%,PEF,FEF25,FEF75,FEF2575 |
Touchscreen | No |
Type | Hand-held Spirometer |
Usage/Application | Clinic,Hospital,Diagnostic Center |
USB Port | Yes |
Volume Accuracy | +-3% or 0.05L |
Weight | 150g |
Wireless Testing | Yes |
Spirometer is a hand-held equipment for checking lung conditions, adopts the infrared mode for measuring relative items, and is applicable for hospital, clinique for routine test. Get best price of Contec SP10 Pulmonary Function Test Machine.
Product Description:
- Rechargeable lithium battery with battery power display
- Automatic power off when there is no operation in one minute
- Forced Vital Capacity [FVC], Forced Expired Volume in one second [FEV], the ratio of FEV1 and FVC [FEV1%]. Peak expiratory flow (PEF), 25% flow of the FVC [FEF25], 75% flow of the FVC [FRF75] and average flow between 25% & 75% of the FVC [FRF2575] can be measured and display.
- Besides, the testee condition can be shown by the ratio of the measured value and the predicted value.
- Display: Flow rate -Volume chart, volume —time chart
- Data memory, delete, upload and review
- Trend chart display
- Scaling [Calibration]
- Information prompts when volume or flow goes beyond the limits
- Ratio of FEV1 and FVC can be measured
- Software interface and trend chart display
- Battery backup: 4 hours
Technical Features:
- Max Volume: 10L
- Flow Range : 1L/s~16L/s
- Volume accuracy: ±3% or 0.05L [Whichever is greater]
- Flow accuracy: ±10% or 0.3L/s [Whichever is greater]
- The highest resistance to flow within the measurement is 6Pa/L/s, and this resistance may occur at 14L/s
Optional:
- Wireless Interface Through Bluetooth
Disclaimer: The product images shown are for illustration purposes only and may not be an exact representation of the product. The manufacturer reserves the right to change product images and specifications at any time without notice. Docuses assumes no liability in case the actual product does not match with the product images.